Potential harm and safety evaluation

Safety starts with an explicit potential harm and affected stakeholders. An available, authorized service can still cause harm. This guide assumes a fictional physical integration only to explain evaluation; TDP safety applicability is unknown.

Document content and editorial review: approved on 2026-11-16 by Codex under the repository user’s delegated editorial review. Approval covers the complete explanation and its recorded source and example limits; semantic, mapping, lifecycle, applicability and target states remain independent.

Conceptual overview

%%{init: {'theme':'base','fontFamily':'Arial, sans-serif','themeVariables':{'lineColor':'#8792a2','textColor':'#f8fafc','nodeTextColor':'#f8fafc','primaryTextColor':'#f8fafc','arrowheadColor':'#8792a2','dropShadow':'none','useGradient':false,'edgeLabelBackground':'#252b36','fontSize':'16px'}}}%%
flowchart LR
  accTitle: G12 hazard-based evaluation
  accDescr: Declared harm frames constraints. Stale evidence must be detected, the scenario-defined safe outcome maintained and an actionable warning delivered. Combined behavior requires verification; this is fictional, not a TDP topology.
  H["Stakeholders and harm"]:::context -->|frame| C["Safety constraint"]:::quality
  D["Stale input detected"]:::quality -->|requires| F["Declared safe outcome"]:::quality
  C -->|governs| F
  D -->|requires timely| W["Actionable warning"]:::quality
  F -->|verify combination with| I["Integration and containment"]:::technique
  classDef context fill:#343c4b,color:#f8fafc,stroke:#8792a2,stroke-width:2px
  classDef quality fill:#24452a,color:#f8fafc,stroke:#8792a2,stroke-width:2px
  classDef technique fill:#4b3049,color:#f8fafc,stroke:#8792a2,stroke-width:2px

Text equivalent: potential harm frames the operational constraint. Risk identification detects stale input; fail safe and hazard warning need separate outcome and timing evidence. Verify safe integration across the combination. Provenance: synthetic G12 reasoning; arrows describe evaluation dependencies, not domain membership or verified architecture.

G12 scenario

Assume a fictional sensor/controller/actuator can open a gate beside a worker. The example’s hazard analysis assumes opening on uncertain zone evidence can injure the worker, while holding an already closed gate causes no competing harm during the stated 10-second window. That assumption needs qualified validation in any real system. It establishes no TDP integration, safety-critical class or certification. All numbers and observations below are synthetic and unapproved.

QAS field Declared condition
Stimulus source Authorized command requester plus a sensor communication fault.
Stimulus Request opening while the latest zone reading is three seconds old.
Artifact Frozen fictional controller H1, sensor protocol, actuator and warning channel.
Environment Gate initially closed, worker potentially present, maximum permitted reading age 2 seconds; one failed sensor path and a 10-second observation window.
Response Detect stale evidence, enforce the opening constraint, retain the declared safe closed state through failover and warn the authorized operator.
Response measure Zero opening commands/effects, stale condition identified before any command, correlated actionable warning received within 1 second and before action; closed state verified throughout 10 seconds.

Record request and reading timestamps, known clock uncertainty (illustratively at most 50 ms), controller decisions, actuator acknowledgments and independently observed gate state. Use a clock with common origin for the exercise and reject timing conclusions if uncertainty could cross the deadline. Observe one normal fresh-reading control, one stale-reading trial and one stale-reading failover trial; preserve each outcome rather than average away a harmful action.

The normal control uses a fresh, correct empty-zone reading with no worker in the isolated model and permits the requested opening. It does not waive the stale-trial constraint or prove that a real sensor always reports truthfully.

The warning must identify the affected gate, stale condition, inhibited action and authorized recovery path. A queued log entry is not receipt. Missing warning delivery, a sensor reporting fresh timestamps for old values, and a failover that forgets the constraint remain explicit failure cases for a real investigation. Freshness detection alone cannot prove the zone actually empty.

G12 results and decisions

Synthetic case Observations Decision
A Staleness identified at 0.10 s; controller log records zero opening commands and independent actuator/state observation records zero opening effects; operator receives warning at 0.60 s; closed state maintained through the 10-second trial and failover Passes the qualified stale-input exercise only.
B Gate opens at 0.20 s; warning arrives at 1.40 s Fails the constraint, safe outcome and warning deadline. Warning existence cannot cancel harm.
C Primary inhibits opening; failover opens at 0.30 s using cached approval Fails safe integration and fail-safe behavior even if service continuity improves.

Example: shutdown is a conditional choice. Holding this already closed gate is safe only under the example’s assumptions. A different gate needed for emergency evacuation could make refusal harmful. A real hazard owner must define safe outcomes, degraded operation and competing harms before selecting shutdown, refusal or failover.

Case A supplies no probability of harm or general assurance. Other hazards, sensor deception, mechanical faults and multiple failures remain untested. Owners must decide actual applicability, stakeholders, hazards, integration assumptions, tolerable risk, warning recipients, deadlines and competent review. No risk acceptance, safety claim, investment or target is approved here.

Techniques and trade-offs

Compare a warning-only baseline B with a constraint-enforcing treatment A using the same initially closed gate model, timestamp trace, clock uncertainty, fault injection and independent state observation. The synthetic treatment avoids the opening in this trace; no real intervention was executed. Record design, hazard review, instrumentation and repeated verification effort, plus delayed work and operator burden, before choosing a real treatment.

Question / technique Benefit and prerequisites Cost, interaction and rejection
Safety: explicit hazard constraints Can expose competing harms if qualified stakeholders define them. Analysis and continuing change review cost effort; reject an unexamined universal shutdown rule.
Operational constraint: interlock Can inhibit a prohibited command if inputs and actuator enforcement are trustworthy. Validation and bypass management cost effort; reject any out-of-bound effect.
Risk identification: freshness check Can detect the named stale condition with bounded clocks and trustworthy timestamps. Sensor faults and false detections remain; reject missed or late detection.
Fail safe: qualified fallback Can preserve the defined safe outcome through the specified failure. May interrupt useful service; reject unsafe failover even if availability rises.
Hazard warning: acknowledged actionable alarm Can support intervention with recipient/access and timing evidence. Alert fatigue, channel failures and training cost; reject late or uncorrelated receipt.
Safe integration: contract/fault exercise Can expose timing, units and stale-state mismatches across components. Combination testing and version maintenance cost; reject individually passing parts with unsafe combined behavior.
C108 fault isolation: containment boundary Can limit propagation if dependencies and shared paths are known. Isolation can block essential signals or fallback; reject a boundary that hides danger or moves harm elsewhere.

Fault isolation is a tactic, not proof of safety or a duplicate of testing isolation. Check shared dependencies and communication loss. Security controls remain necessary, but correct authorization alone cannot guarantee safe action. Account for implementation, maintenance, lost service and verification costs; any real treatment needs repeated fault trials and qualified review beyond this documentation.

Aliases and source limits

C205 Fail-safe is a proposed scoped adjective mapping to Fail safe; it supplies no universal equivalence or generic safe state. Software risk identification is distinct from a human risk-assessment workshop.

The ISO/IEC 25010:2023 catalogue, consulted 2026-11-16, confirms edition 2 and model scope, not these detailed definitions. The research intake records safety names from an earlier preview; no PDF or full standard was inspected here. Exact mappings remain proposals. Q42 is primary for its own safe tag and secondary for external attributions. Local safety definitions, lifecycle assessments and TDP applicability remain pending; no backend was read.

Audience paths

Read the executive decisions and technical evaluation.