Skip to content
English

Reliability and operations

Document content and editorial review: approved on 2026-11-17 by Codex under the repository user’s delegated review. Approval covers this explanation and its stated evidence limits; semantic, mapping, lifecycle and target states remain independent.

This editorial family compares six approved local quality concepts using G02 guidance. It covers availability/reliability and the proposed operational questions below. Semantic, mapping, lifecycle and target approval remain independent.

Conceptual overview

%%{init: {'theme':'base','fontFamily':'Arial, sans-serif','themeVariables':{'lineColor':'#8792a2','textColor':'#f8fafc','nodeTextColor':'#f8fafc','primaryTextColor':'#f8fafc','arrowheadColor':'#8792a2','dropShadow':'none','useGradient':false,'edgeLabelBackground':'#252b36','fontFamily':'Arial, sans-serif','fontSize':'16px'}}}%%
flowchart TD
  accTitle: Separate service readiness from continuity and recovery
  accDescr: Availability asks when service is usable; reliability asks about correct service over an interval. Fault tolerance concerns fault continuity, recoverability restoration, and robustness abnormal conditions. Proposed operational diagnosis and authorized control support recovery evaluation.
  A["Availability: usable when required"]:::quality ---|different question| R["Reliability: correct over an interval"]:::quality
  R -->|evaluate fault continuity separately| F["Fault tolerance"]:::quality
  R -->|evaluate restoration separately| C["Recoverability"]:::quality
  B["Robustness: abnormal conditions"]:::quality -->|contrasts with| N["Faultlessness: normal conditions"]:::quality
  O["Operational diagnosis and authorized control"]:::quality -->|support evaluation of| C
  classDef quality fill:#24452a,color:#f8fafc,stroke:#8792a2,stroke-width:2px

Text equivalent: Availability and Reliability ask different questions. Fault tolerance and Recoverability distinguish continuity from restoration. Robustness handles abnormal conditions; Faultlessness is a normal-operation quality. Edges compare questions; they assert no ISO parentage, equivalence or causal guarantee.

Operational diagnosis and control support recovery evaluation; the grouped node abbreviates observability, operability and administration, not a merged concept. This added arrow comes from synthetic G13; successful recovery still needs separate data evidence.

Provenance: editorial synthesis of linked approved local concepts and synthetic G02. Source and edition limits remain explicit. No backend observation or approved service level is established.

Operational diagnosis

G13’s early overview relates operational observability to diagnosis, operational operability to service control and administrability to authorized change. These are local proposals and evaluation relationships, not a framework hierarchy. Interaction operability and testing observability retain separate questions.

A synthetic early alert without operation correlation fails diagnosis; a quick recovery losing data fails preservation. Monitoring and updating are tactics/activities, not new qualities. Read the executive consequences and technical method; actual TDP applicability and targets are pending.

Compare the questions

Concept Question and concrete use Limit
Availability Is the declared service usable when required? G02 A is up for 3,580/3,600 s Its 99.444…% does not erase the 20 s interruption
Reliability Does service remain correct for the stated interval? Count service failures separately from request errors A short recovery still interrupts a failure-free interval
Fault tolerance Does required work continue during the declared fault? Strict variant C loses no valid reads Tolerating one stopped instance does not cover shared-store failure
Recoverability Are service and affected data restored within the stated bounds? G02 B preserves 60 updates but takes 80 s Starting a process or possessing a backup is insufficient
Robustness Are abnormal inputs handled without corrupting state or disrupting valid work? G02-R rejects 100 malformed requests Invalid-input rejection is not a valid-service error
Faultlessness Does the stated normal-operation control complete without observed failure? Normal-run evidence cannot prove latent defects absent or confirm ISO wording

Example: a recovery pass can fail continuity. Synthetic G02 A restores correct service after 20 s and satisfies its illustrative time and data criteria. It loses 200 reads during that interruption, so it fails a stricter zero-failed-read continuity requirement. See the worked results. These are unapproved example criteria, not TDP measurements or commitments.

Measures, labels and decisions

Uptime, downtime and MTBF are measures with observation boundaries, not three additional qualities. Dependable/dependability is a broad reading aggregate; security and safety need their own scoped review. Consistent remains an unresolved label rather than an independent concept. Available, Recoverable, Fault-tolerant, fault-tolerance and Robust retain related mapping proposals, not confirmed synonymy. Security’s availability concern reuses the same availability identity without inferring framework parentage.

The executive narrative frames value, risk and owner decisions. The technical narrative explains controlled comparisons, costs and rejection criteria. Both PDF exports derive from those canonical narratives. Lifecycle groups derive from each concept’s own assessment.

Contents